Glass or Mesh Door for a Data Cabinet? How to Choose

By In Touch Telecoms Ltd

Choose your data cabinet door by checking where your equipment draws in cool air and where it exhausts warm air. If your servers draw air in at the front and exhaust it at the rear, start by looking at mesh doors at both ends. A glass front can suit a smaller network setup if the cabinet’s other vents provide the airflow your equipment requires with the door closed.

When mesh is the better choice

A mesh door lets air pass through its face. If your equipment needs a clear path from front to back, check both ends of the cabinet. A mesh front door can help air get in, but the warm air still needs a route out. Check the ventilation at the rear, leave room between the cabinet and the wall, and route cable bundles away from equipment exhausts.

Mesh makes it easier for air to move through the cabinet. The room still needs to supply air cool enough for the equipment and remove the heat it produces. That matters in a small comms cupboard, where warm exhaust air can collect and find its way back to the equipment intakes.

When a glass door can work

A glass front lets you see status lights without opening the cabinet. It can work for a compact layout with a patch panel, router and switch if the cabinet’s vents and clearances suit those devices. Check where each device takes in and exhausts air. A switch with side vents, for example, needs space beside it for air to move, whichever front door you choose.

Check the full air path before ordering

  1. Read the equipment specs. Check the intake and exhaust positions, required clearances and permitted inlet temperatures for each device.
  2. Look at the cabinet as a whole. Check the front and rear doors, side panels and top vents. Allow for shelves, power strips and cables that may sit near an intake or exhaust.
  3. Check the room. Leave space around the cabinet where it vents, and consider how warm the room gets during typical use.
  4. Verify the setup after installation. With the doors closed and the equipment running under normal load, check inlet temperatures against the manufacturer’s limits. If you can, check again during the busiest or warmest part of the day.

Prism door options vary by model. If you’re ordering a cabinet for a server, a PoE switch or a mix of equipment, send us the cabinet size and equipment model numbers. We can confirm the door options for your chosen cabinet and quote for the configuration.